Support∣CHIAYO

EXCELLENCE IN SOUND

  • Product
    Wireless PA System

    Wireless PA System

    Wireless Microphone

    Wireless Microphone

    Antenna System

    Antenna System

    Infrared Microphone

    Infrared Microphone

    Transmitter

    Transmitter

    Module

    Module

    Tour Guide Microphone

    Tour Guide Microphone

    Conference Microphone

    Conference Microphone

    Wired Microphone

    Wired Microphone

    Accessories

    Accessories

  • Application
    Large Events

    Large Events

    Medium and Small Events

    Medium and Small Events

    Classroom

    Classroom

    Tour Guides

    Tour Guides

    Stage / Religious Events

    Stage / Religious Events

    Meetings / Classrooms

    Meetings / Classrooms

    Long-Range Audio Solutions

    Long-Range Audio Solutions

    Indoor Audio Solutions

    Indoor Audio Solutions

  • Support
  • News
  • Profile
  • Sitemap
  • Contact
  • Inquiry
  • 繁中 EN
Support

Frequently asked questions

Frequently asked questions

Simple DIY trouble shooting

Case Studies

  • How many devices can be connected to the conference system? How many wired gooseneck microphones can be installed?

    Chiayo conference systems can typically connect dozens to hundreds of devices, depending on the environment and model. For configurations requiring 30 to 50 units, we recommend using the GM-243C/S and GMC-60 series conference systems.

  • What is the difference between GM-243C and GM-243S?

    GM-243C is for chairman. Besides TALK button, it's added a chair priority button (MUTE) which can control the speech of all delegates.
    GM-243S is for delegate and only has a talk button (TALK).

  • What are GMC-10 +, GMC-30 and GMC-60 for?

    GMC-10 +, GMC-30 and GMC-60 are audio converters that can deliver the audio from the conference system to an amplifier or mixer.

  • What is the difference among GMC-10 +, GMC-30, GMC-60?

    GMC-10+ can connect up to 10 units of GM-243 in series and require power from one GM-243 unit. GMC-30 can connect up to 30 units of GM-243 in series and power the system. GMC-60 can connect up 60 units of GM-243 and power the system.

  • What is the input power for the GM-243 conference system?
    • INPUT:100-240VAC
    • OUTPUT:15VDC/4.34A
  • Is it possible to install multiple GM-243C chairman units in the same loop of the conference system?

    Two GM-243C at max can exist in the same loop.

  • How to set the SYSTEM SWITCH (C/S) of GMC-10+, GMC-30 and GMC-60?

    If any GM-243C is in the same loop of conference system, set switch at "C". If all microphones are GM-243S, switch at "S".

    How to set the SYSTEM SWITCH (C/S) of GMC-10+, GMC-30 and GMC-60?

    If any GM-243C in the GMC-60/30 system, switch to "C".

    How to set the SYSTEM SWITCH (C/S) of GMC-10+, GMC-30 and GMC-60?

    If no GM-243C in the GMC-60/30 system, switch to "S".

    How to set the SYSTEM SWITCH (C/S) of GMC-10+, GMC-30 and GMC-60?

    If any GM-243C in the GMC-10+ system, switch to "C".

    How to set the SYSTEM SWITCH (C/S) of GMC-10+, GMC-30 and GMC-60?

    If no GM-243C in the GMC-10+ system, switch to "S".

  • Is GM-243C's chairman priority able to control all 118 units of GM-243S?

    Two GMC-60 have to be connected with CAT-5e cable via the LINK sockets on the rear panels as the same loop that enables GM-243C to control all 118 GM-243S units.

    Is GM-243C's chairman priority able to control all 118 units of GM-243S?

    Connect both LINK sockets and switch system to "C" to become the same loop and control all 118 GM-243S units.

  • What should I notice during GM-243 conference system installation?
    • Do not power on during installation to prevent the devices from damages by short circuit due to poor cable quality.
    • Do not use cables of unknown origins, which may cause system errors. Cat.5e / Cat.6 cables of CHIAYO or other internationally-approved origins would be recommended.
    • If it's necessary to diy cables required by installation, be sure to examine them with RJ-45 cable tester until no problem before installation.
  • How to install GM-243 unit to the inputs (PORT) of GMC-10 +, GMC-30 and GMC-60?

    Each port can only connect up to 10 units of  GM-243 in series. GMC-10+ has only one port, GMC-30 has three and GMC-60 has six.

  • Why doesn't the port indicator(s) on the front panel light up?

    The port indicator lights up only with its corresponed port connected with GM-243 unit. It won't light up without GM-243 even there is a cable connected.

  • How to set with the MIC / LINE output impedance switch of GMC-10+?

    If you would like to output the audio to MIC IN of the amplifier or mixer, please switch to MIC; if to the LINE IN or AUX IN, please switch to LINE.

    How to set with the MIC / LINE output impedance switch of GMC-10+?

    Switch to "MIC" if connecting to "MIC" jack of the amplifier / mixer.

    How to set with the MIC / LINE output impedance switch of GMC-10+?

    Switch to "LINE" if connecting to "LINE" or "AUX" jack of the amplifier / mixer.

  • 1
  • 2
  • next
  • Profile

    About CHIAYO Product development Certificate
  • Product

    Wireless PA System Wireless Microphone Antenna System Infrared Microphone Transmitter Module Tour Guide Microphone Conference Microphone Wired Microphone Accessories
  • Contact

    If you have questions regarding our products, please email us at sales@chiayo.com.tw

Support∣CHIAYO

EXCELLENCE IN SOUND

  • follow
Copyright © 2025 CHIAYO All Rights Reserved.
EN
繁中 EN